Cleanroom Laundry · Built to Specification

Purity, engineered into every single thread.

Contamination-controlled washing and drying for the world’s most regulated environments — barrier-isolated, HEPA-filtered and validated to your cleanroom classification.

ISO 14644 classified HEPA H14 filtration AISI 316L electropolished CE / AENOR certified

The stakes

When a single particle can fail a batch, ordinary laundry isn’t an option. Cleanroom textiles demand contamination control engineered into every wash, every dry, every cycle.

The barrier principle

Two doors. Two worlds. Zero cross-contamination.

Our pass-through barrier washers are built into the cleanroom wall itself. Soiled textiles load from the non-classified side; sterile textiles are unloaded into the classified zone. The two never meet.

DOMUS cleanroom pass-through barrier washer

Aseptic separation, by design

  • Two opposed doors with an aseptic partition physically separate the classified and non-classified zones.
  • HEPA H14 filtered air and stainless manifolds keep intake air to the cleanest classification.
  • Interlocked cycle logic means the clean-side door only opens once the load is validated — never both at once.
  • AISI 316L electropolished drum and vat resist microbial adhesion and withstand aggressive validated chemistry.
375G-Factor spin — lower residual moisture
H14HEPA filtration · 99.995% efficient
16–100 kgBarrier washer capacity range
316LMedical-grade electropolished steel
Why it matters

Compliance you can prove, protection you can trust.

Regulated environments don’t reward good intentions — they demand documented, repeatable, auditable control. Every machine is engineered to deliver it.

Cross-contamination control

Physical barrier separation and unidirectional flow stop particulate and microbial transfer between zones.

Regulatory alignment

Engineered to support ISO 14644 cleanroom classes and GMP Annex 1 sterile-manufacturing requirements.

Validated & traceable

Programmable, locked cycles with calibrated probes and full data logging for validation and audit trails.

Residual-moisture control

A high 375 G-Factor extracts more water, shortening sterile-safe drying and cutting energy per cycle.

Particle & microbial control

Electropolished 316L surfaces and HEPA-filtered air minimise the surfaces and pathways contamination needs.

IoT audit trail

DOMUSCONNECT telemetry records every cycle for statistics, traceability and remote technical support.

The range

Barrier washers & cleanroom dryers, 11kg to 100kg.

A complete, matched line — every model configurable to your classification, chemistry and throughput. Built to order, not off the shelf.

Barrier Washers

6 models · 24.5–100 kg
Domus ASA-100 barrier washer
ASM-22
24.5 kg
Pass-through barrier · TOUCH II · HEPA-ready
DHB-27
30 kg
G-Factor 375 · dual heating · Pullman drum opt.
DHB-35
38.8 kg
G-Factor 375 · 316L option · weighing opt.
DHB-50
54.3 kg
High-throughput · dual heating · 316L option
DHB-70
77.7 kg
High-throughput · indirect steam option
ASA-100
100 kg
Flagship capacity · external heat exchanger opt.

Cleanroom Dryers

9 models · 11.7–83.3 kg
Domus DTT-80 cleanroom dryer
DTT-11
11.7 kg
DOUBLE FLOW · HEPA 13/14 · SOFT DRY
DTT-14
15 kg
DOUBLE FLOW · HEPA 13/14 · reversing
DTT-18
18.3 kg
DOUBLE FLOW · HEPA-ready · COOL DOWN
DTT-22
24.4 kg
316L option · calibrated probe · humidity sensor
DTT-28
30.6 kg
Reinforced drum · HEPA 13/14 · EFFICIENT DRY
DTT-35
36.7 kg
Reinforced drum · HEPA 13/14 · 316L option
DTT-45
50 kg
Geared drive · DOUBLE FLOW · high output
DTT-60
66.7 kg
Geared drive · high throughput · COOL DOWN
DTT-80
83.3 kg
Flagship dryer · geared drive · SOFT DRY
Where it’s critical

Trusted where contamination isn’t an option.

From sterile drug manufacture to microchip fabrication, our cleanroom laundry supports the sectors where the smallest particle carries the highest cost.

Pharmaceutical & biotech

Sterile manufacturing, GMP Annex 1 gowning and aseptic processing textiles.

Hospitals & sterile services

Operating-theatre textiles, CSSD gowns and reusable barrier garments.

Semiconductor & micro-electronics

Particle-critical fabrication garments where nanometre defects mean scrap.

Aerospace & precision

Contamination-controlled assembly and optics-grade cleanroom workwear.

Food, beverage & dairy

Hygiene-zone garments for HACCP-controlled and high-care production.

Laboratories & research

Controlled-environment coats and garments for R&D and analytical labs.

Cosmetics & personal care

Fill-and-finish cleanroom textiles for particle-sensitive formulation.

Nuclear & controlled zones

Monitored-area workwear where controlled handling is non-negotiable.

Engineering inside

Every detail built for the cleanroom.

DOMUS engineering, specified for contamination control — the technology that turns a washer into validated infrastructure.

TOUCH II — dual screen

A 7″ fully programmable controller on both sides of the barrier, 37 languages, USB and locked validated cycles.

DOMUSCONNECT IoT

Standard telemetry, remote technical service and laundry management — every cycle logged for traceability.

HEPA H13 / H14 filtration

Stainless AISI 304 HEPA filtration with prefilter on intake air, keeping the wash environment to classification.

AISI 316L electropolished

Medical-grade stainless drum and vat, electropolished to resist microbial adhesion and validated chemistry.

SOFT DRY & COOL DOWN

Stamped-hole drum and anti-wrinkle cool-down protect delicate cleanroom fabrics through the drying phase.

Intelligent consumption

Automatic water and chemistry dosing with 8 signals as standard, plus wet-cleaning and imbalance control.

Built to specification

From your classification to a validated install.

Cleanroom laundry is never off-the-shelf. We engineer each system to your zone, throughput and validation requirements — and support it for life.

1

Consult & survey

We assess your classification, textiles, throughput and utilities on site.

2

Specify & design

Barrier layout, HEPA level, heating, chemistry and validation defined to spec.

3

Manufacture to order

Your machines are built and configured — 316L, panels and options as required.

4

Install & validate

Through-wall installation, commissioning and documentation to support validation.

5

Support & telemetry

Planned maintenance, genuine parts and IoT-backed remote support, ongoing.

Certified & compliant

Engineering that stands up to audit.

CE Approved AENOR Certified ISO 14644 Cleanroom Classes GMP Annex 1 Aligned AISI 316L Medical-Grade
Let’s specify yours

Cleanroom laundry, engineered to your classification.

Tell us your cleanroom class, textiles and throughput. Our specialists will design a barrier washing and drying solution built precisely to your requirement.

Bespoke · built to order · UK-wide supply, installation and validation support